Electromagnetic Fault Injection (EMFI) Equipment
Motorized EMFI bench
XYZ resolution 1 µm
XY repeatability 5 µm
Travel range 125 × 75 mm
Z range 25 mm
Programmable control.
HV pulse generator
±750 V peak, 0.75 V resolution, 1.5 ns rise time, typical pulse duration 6 ns at maximum amplitude
Single-shot and repetition up to 1 kHz
Integrated triggering and delay control.
Injection probe kit
10 probes with contact and non-contact variants
Including anti-bounce probes to eliminate reflections and improve pulse shape.
SCA measurement probes
Langer RF 0.3–3 probes and ICR probe HH500-6 with PA303 pre-amplifier for emission acquisition.
Oscilloscope
Lecroy Wavesurfer 404HD
4 GHz bandwidth, 20 GS/s
Tombak pulse delay generator
Fine latency control with 10 ps resolution and 80 ps RMS jitter.
Useful for temporal alignment between DUT execution trigger and EM pulse.
ColdReset system
Programmable remote power cut and power cycling for the DUT.